{"product_id":"bile-duct-training-model-surgical-anastomosis-hepatobiliary-simulator","title":"Bile Duct Training Model | Surgical Anastomosis \u0026 Hepatobiliary Simulator","description":"\u003cp\u003eThe Bile Duct Training Model is a realistic surgical simulator designed to support the development of hepatobiliary and pancreatic surgical techniques.\u003c\/p\u003e\n\n\u003cp\u003eThis model replicates the structure and behaviour of the human bile duct, allowing surgeons and trainees to practise delicate procedures such as duct-to-mucosa anastomosis and bile duct repair. The realistic tubular structure provides tactile feedback similar to biological tissue when cutting and suturing.\u003c\/p\u003e\n\n\u003cp\u003eSimulation-based training allows clinicians to practise complex procedures repeatedly in a controlled environment, improving surgical precision and confidence before performing procedures on patients.\u003c\/p\u003e\n\n\u003cp\u003eThe bile duct model is particularly useful for training in pancreatic surgery and hepatobiliary procedures, where precise suturing techniques are critical. Studies evaluating similar training models report high levels of realism for suturing behaviour and tissue handling during pancreatic surgery training.\u003c\/p\u003e\n\n\u003cp\u003eThe model is widely used in medical schools, surgical residency programmes, teaching hospitals and surgical skills laboratories.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTraining Applications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis surgical training model can be used for practising a range of procedures including:\u003c\/p\u003e\n\n\u003cp\u003e• Duct-to-mucosa anastomosis\u003cbr\u003e\n• Hepatobiliary surgical suturing\u003cbr\u003e\n• Pancreatic surgery training\u003cbr\u003e\n• Biliary reconstruction techniques\u003cbr\u003e\n• Gastrointestinal surgical suturing\u003cbr\u003e\n• Surgical skills laboratory training\u003cbr\u003e\n• Medical student surgical education\u003cbr\u003e\n• Surgical training workshops\u003c\/p\u003e\n\n\u003cp\u003eThese procedures are fundamental for surgeons training in hepatobiliary and pancreatic surgery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe bile duct training model is engineered to replicate the behaviour of real tissue during surgical procedures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey features include:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e• Realistic bile duct structure\u003cbr\u003e\n• Suitable for suturing and surgical instruments\u003cbr\u003e\n• Designed for hepatobiliary surgical training\u003cbr\u003e\n• Easy to handle and maintain\u003cbr\u003e\n• Non-toxic training material\u003cbr\u003e\n• Biohazard-free simulation model\u003cbr\u003e\n• Odourless reusable design\u003c\/p\u003e\n\n\u003cp\u003eThese features create a safe and repeatable environment for developing advanced surgical techniques.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFULL Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eModel Type\u003cbr\u003e\nHepatobiliary surgical training simulator\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003e6 inches\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eInternal Diameter (ID)\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003e8.5 mm\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eOuter Diameter (OD)\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003e11 mm\u003c\/li\u003e\n\t\u003cli\u003e\u003cstrong\u003eWall Thickness\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli\u003e1.25 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003cbr\u003e\nSynthetic soft-tissue simulation material\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eTraining Use\u003c\/strong\u003e\u003cbr\u003e\nDuct-to-mucosa anastomosis and hepatobiliary surgical training\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCompatible Procedures\u003c\/strong\u003e\u003cbr\u003e\nSuturing and surgical reconstruction techniques\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIdeal Training Environments\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eThis hepatobiliary training model is commonly used in:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e• Surgical skills laboratories\u003cbr\u003e\n• Medical schools and universities\u003cbr\u003e\n• Pancreatic surgery training programmes\u003cbr\u003e\n• Teaching hospitals\u003cbr\u003e\n• Clinical training centres\u003cbr\u003e\n• Surgical education workshops\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSimulation models allow surgeons to practise procedures repeatedly while improving accuracy and technique.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Precision Dermal","offers":[{"title":"Default Title","offer_id":57773216956751,"sku":"LL-TRN-0325","price":36.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1019\/1041\/3647\/files\/LL-TRN-0325-2.jpg?v=1779663663","url":"https:\/\/www.suturesupplyco.co.uk\/products\/bile-duct-training-model-surgical-anastomosis-hepatobiliary-simulator","provider":"Suture Supply Co.","version":"1.0","type":"link"}