Compare USP 1 sutures across polyglactin 910, polydioxanone, nylon, polypropylene and poliglecaprone 25 materials, plus specialist knotless systems and ligatures. Filter by absorbability, construction, strand length, needle specification, arming, brand and catalogue reference.

Shop 1 sutures Use the filters below to narrow by material, construction and needle.
USP 1 Absorbable & non-absorbable Monofilament & braided Needled & non-needled

Compare 1 suture materials

USP 1 identifies the nominal suture size, not the complete product. This heavy suture range spans absorbable and non-absorbable families used where substantial wound support may be specified, with different constructions, absorption profiles, colours, strand lengths and needle configurations.

Product groupMaterial and formatVerify before ordering
VICRYL familiesPolyglactin 910 absorbable braided suturesVerify coated or rapid family, colour, strand, absorption designation, needle profile, arming and code.
PDS PlusPolydioxanone absorbable monofilamentMatch antibacterial product family, colour, strand, needle code, point profile and complete reference.
PROLENE & LUXYLENEPolypropylene non-absorbable monofilamentConfirm brand, colour, strand length, needle code, dimensions, point profile, arming and product code.
ETHILON, LUXAMID & NUROLONNylon non-absorbable monofilament or braided ligatureMatch construction, colour, strand, needle or non-needled format, dimensions, pack and catalogue reference.
MONOCRYL familiesPoliglecaprone 25 absorbable monofilamentConfirm standard or PLUS family, strand, colour, needle specification, pack size and catalogue code.
STRATAFIXProduct-specific knotless tissue-control systemsConfirm material, absorption profile, directional design, strand, needle, device format and catalogue reference.

Understand the 1 needle specification

The intended USP 1 range includes conventional cutting, reverse cutting, taper point, TAPERCUT, blunt and specialist configurations. Products can also differ by needle dimensions, curvature, single- or double-armed presentation, control-release format and non-needled ligatures.

Needle groupExamples in the rangeImportant selection details
Taper pointCT, CT-2, CTX, MH-1, HR and product-specific codesConfirm the exact code, needle dimensions, curvature, strand, material and arming.
Cutting profilesConventional cutting and reverse cutting configurationsDo not treat cutting descriptions as interchangeable; verify the complete manufacturer wording.
TAPERCUTCombined taper and cutting configurations, including veterinary optionsMatch the branded needle profile, dimensions, curvature, strand and catalogue code.
Blunt & ligature formatsBlunt point, control-release and non-needled productsCheck geometry, dimensions, number of needles, strand length and complete reference.

Find the correct 1 suture

Start with the original box, theatre list or authorised purchasing specification. Products sharing the USP 1 size can differ materially by construction, absorbability, colour, strand length, needle geometry, arming, pack quantity and manufacturer code.

Confirm material and product familyMatch polyglactin 910, polydioxanone, nylon, polypropylene, poliglecaprone 25 or the specified knotless system.
Match strand and needleCheck length, colour, needle code, point profile, dimensions, curvature, technology and arming.
Verify the complete product codeConfirm the full manufacturer reference and pack quantity before ordering.
USP size1 heavy surgical configurations
Materials representedPolyglactin 910, polydioxanone, nylon, polypropylene and poliglecaprone 25
Selection basisMaterial, product family, absorption profile, strand, needle, arming, pack quantity, code and current IFU

1 sutures FAQs

What product families are included in the 1 collection?

The intended USP 1 range includes VICRYL, VICRYL RAPIDE, PDS, ETHILON, PROLENE, MONOCRYL, LUXYLENE, LUXAMID, NUROLON and STRATAFIX products.

Does the collection include absorbable and non-absorbable sutures?

Yes. Polypropylene and nylon products are non-absorbable, while the polyglactin 910, poliglecaprone 25 and polydioxanone families are absorbable. STRATAFIX specifications vary by product, so confirm the current manufacturer labelling.

Are all 1 sutures interchangeable?

No. Products at the same USP size can differ by material, absorption profile, construction, colour, strand length, needle geometry, arming and pack quantity.

Which needle profiles are represented?

The intended range includes taper point, conventional cutting, reverse cutting, TAPERCUT, blunt and product-specific specialist configurations, as well as non-needled ligatures.

Does the range contain single- and double-armed sutures?

Yes. Both configurations are represented. Match the number of needles, each needle code, dimensions, curvature and strand length to the required specification.

How do I identify the correct 1 product?

Match the brand, material, product family, absorbability, construction, colour, strand, complete needle specification, arming, pack quantity and catalogue code.

Professional-use information: This page supports product identification and purchasing only and is not clinical guidance. Product availability, packaging and specifications can change. Qualified healthcare professionals should confirm suitability and consult the manufacturer’s current labelling and instructions for use.